Fault Detection and Isolation Method Based on H−/H∞ Unknown Input Observer Design in Finite Frequency Domain
From MaRDI portal
Publication:4597544
DOI10.1002/asjc.1490zbMath1386.93213MaRDI QIDQ4597544
Yi Shen, Meng Zhou, Zhen-Hua Wang
Publication date: 13 December 2017
Published in: Asian Journal of Control (Search for Journal in Brave)
Full work available at URL: https://doi.org/10.1002/asjc.1490
linear matrix inequalities; fault detection and isolation; finite frequency domain; unknown input observer design
90B25: Reliability, availability, maintenance, inspection in operations research
93C95: Application models in control theory
93C05: Linear systems in control theory
93C15: Control/observation systems governed by ordinary differential equations
Related Items
Sensor Fault Diagnosis Based on a Sliding Mode and Unknown Input Observer for Takagi‐Sugeno Systems with Uncertain Premise Variables, Unknown Input Reduced‐order Observer Design for One‐Sided Lipschitz Nonlinear Descriptor Markovian Jump Systems, Diagnosis of Partially Observed Petri Net Based on Analytical Redundancy Relationships, Comment and Further Result on “Fault Detection and Isolation Method Based on H−/H∞ Unknown Input Observer Design in Finite Frequency Domain”