All-integrator approach to linear SISO control system analysis using block pulse functions (BPF) (Q677511): Difference between revisions

From MaRDI portal
ReferenceBot (talk | contribs)
Changed an Item
Set OpenAlex properties.
 
Property / full work available at URL
 
Property / full work available at URL: https://doi.org/10.1016/s0016-0032(96)00054-3 / rank
 
Normal rank
Property / OpenAlex ID
 
Property / OpenAlex ID: W2057450362 / rank
 
Normal rank

Latest revision as of 11:12, 30 July 2024

scientific article
Language Label Description Also known as
English
All-integrator approach to linear SISO control system analysis using block pulse functions (BPF)
scientific article

    Statements

    All-integrator approach to linear SISO control system analysis using block pulse functions (BPF) (English)
    0 references
    0 references
    0 references
    0 references
    10 November 1997
    0 references
    This paper makes use of the \(m\)-term block pulse function (BPF) domain operational matrix (with \(h\) as the duration of each component BPF) for the following differentiation \[ \begin{multlined}\text{D1}_{(m)}=\text{P1}^{-1}_{(m)}={1\over h}\left\lceil\begin{matrix} {1\over 2} & 1 &\cdots &\cdots & 1 & 1\\ &{1\over 2} & 1 &&& 1\\ &&\ddots &\ddots &&\vdots\\ &&&\ddots &\ddots &\vdots\\ & 0 &&&\ddots & 1\\ &&&&&{1\over 2}\end{matrix}\right\rceil^{-1}\\ ={1\over h}\left[\begin{matrix} 2 & -4 & 4 &\cdots &\cdots &(-1)^{m-1}4\\ & 2 &-4 & 4 &&\vdots\\ &&\ddots &\ddots &\ddots &\vdots\\ &&&\ddots &\ddots & 4\\ & 0 &&&\ddots &-4\\ &&&&& 2\end{matrix}\right]\end{multlined} \] to find out a block pulse operational transfer function (BPOTF) in the form of \[ |G(s)|_{s=\text{D1}_{(m)}}= G[\text{D1}_{(m)}]=\text{BPOTF}_{(m)}. \] Analysis of simple linear control systems using the BPOTF shows that the results are not accurate when compared with the direct expansion of the exact solution in the BPF domain. To remove this defect, one shot operational matrices for repeated integration introdudced by Rao et al. (1983), \[ \begin{multlined}\text{Pn}_{(m)}={1\over h}\begin{vmatrix} pn1 & pn2 &\cdots &\cdots & pnm\\ & pn1 & pn2 &&\vdots\\ &&\ddots &\ddots &\vdots\\ & 0 &&\ddots & pn2\\ &&&& pn1\end{vmatrix},\\ pnj=\begin{cases} 1,\quad & j=1\\ j- 2(j-1)^{n+1}+ (j-2)^{n+1},\quad &j\geq 2\end{cases}\end{multlined} \] are used to develop a modified BPOTF for linear SISO control system analysis in the BPF domain. A few typical linear SISO control systems are analyzed using the modified BPOTFs as illustrative examples. The results are found to match exactly with the direct BPF expansions of the exact solutions.
    0 references
    linear system analysis
    0 references
    all-integrator approach
    0 references
    block pulse function
    0 references
    0 references

    Identifiers

    0 references
    0 references
    0 references
    0 references
    0 references
    0 references