Non-minimum phase switched systems: HOSM-based fault detection and fault identification via Volterra integral equation
From MaRDI portal
Publication:2800922
Observability (93B07) Variable structure systems (93B12) Linear systems in control theory (93C05) Control/observation systems governed by ordinary differential equations (93C15) Control/observation systems governed by functional relations other than differential equations (such as hybrid and switching systems) (93C30)
Recommendations
- State observation for nonlinear switched systems using nonhomogeneous high-order sliding mode observers
- Continuous and discrete state reconstruction for nonlinear switched systems via high-order sliding-mode observers
- Fault detection for linear switched systems based on \(H\_/{H_\infty}\) unknown input observers
- High-order sliding mode observers for nonlinear autonomous switched systems with unknown inputs
- Hybrid sliding mode observer for switched linear systems with unknown inputs
Cites work
- scientific article; zbMATH DE number 1260395 (Why is no real title available?)
- scientific article; zbMATH DE number 1794357 (Why is no real title available?)
- A strong controllability and observability in linear multivariable control
- Design and analysis of robust residual generators for systems under feedback control
- Design of a robust fault detection based observer for linear switched systems with external disturbances
- Dynamical properties of hybrid automata
- Exact Differentiation of Signals With Unbounded Higher Derivatives
- Failure detection and reconstruction in switched nonlinear systems
- Finite-time converging jump observer for switched linear systems with unknown inputs
- HOSM Observer for a Class of Non-Minimum Phase Causal Nonlinear MIMO Systems
- High-order sliding mode observers for nonlinear autonomous switched systems with unknown inputs
- High-order sliding-mode observation for linear systems with unknown inputs
- Higher-order sliding modes, differentiation and output-feedback control
- Invertibility of switched linear systems
- Nonlinear observer for autonomous switching systems with jumps
- Nonlinear robust fault reconstruction and estimation using a sliding mode observer
- Observation of linear systems with unknown inputs via high-order sliding-modes
- Partial unknown input reconstruction for linear systems
- Robust exact finite-time output based control using high-order sliding modes
- Robust finite time observer design for multicellular converters
- Robust reconstruction of the discrete state for a class of nonlinear uncertain switched systems
- Robust state estimation and fault diagnosis for uncertain hybrid nonlinear systems
- Simultaneous state and input estimation of hybrid systems with unknown inputs
- Sliding mode estimation schemes for incipient sensor faults
- Sliding mode methods for fault detection and fault tolerant control with application to aerospace systems
- Sliding mode observers for fault detection and isolation
- Stability and Stabilizability of Switched Linear Systems: A Survey of Recent Results
- State Estimation and Sliding-Mode Control of Markovian Jump Singular Systems
- State observation for nonlinear switched systems using nonhomogeneous high-order sliding mode observers
- Strong detectability and observers
- Support Theory for Preconditioning
- Switched Observers for Switched Linear Systems With Unknown Inputs
Cited in
(8)- Fault identification: an approach based on optimal control methods
- State estimation for linear hybrid systems with periodic jumps and unknown inputs
- Fault identification in nonlinear dynamic systems not satisfying matching, minimum phase, and detectability conditions
- A novel sliding mode observer for state and fault estimation in systems not satisfying matching and minimum phase conditions
- Fault detection and approximation for a class of linear impulsive systems using sliding-mode observer
- Fault identification in nonlinear systems based on sliding mode observers with weakened existence conditions
- Continuous and discrete state estimation for switched LPV systems using parameter identification
- Sliding mode observers for fault identification in linear systems not satisfying matching and minimum phase conditions
This page was built for publication: Non-minimum phase switched systems: HOSM-based fault detection and fault identification via Volterra integral equation
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q2800922)